+44 (0)1628 825 555 info@conceptsmoke.com
Concept Smoke Systems Concept Smoke Systems
  • About Smoke
    • About Smoke Overview
    • Smoke Types
    • Smoke Safety
    • Ducting Smoke
    • Particle Size & Settling Velocities
    • Temperature Resistance
    • Smoke Hang Time Index
  • Applications
    • Applications Overview
    • Military / Defence Training
    • Maritime Fire Training
    • LEV & Clearance Testing
    • Leak Testing
    • Fire Training
    • Wind Tunnel Studies
    • Building Envelope Testing
    • Security Smoke Systems
    • Large Scale Testing
    • PPV Testing
    • Cleanroom Solutions
    • Oil Mist Generation
    • Smoke Detector Testing
  • Products
    • Smoke Generators
      • Portable Battery Operated
      • Portable Mains Operated
      • Gas Powered
      • High Output Mains Operated
      • Thermal Aerosol Generators
      • Pure Water Fogger
      • Specialist
      • Bespoke Design & Manufacture OEM
    • Security Systems
      • Vehicle Security
      • Stand Alone
      • Fixed Installation
      • Security Accessories
      • Bespoke Design & Manufacture OEM
    • Accessories
      • Fan/Smoke Distribution
      • Protective Transit Cases
      • Smoke Density Measurement
      • Smoke Scrubbers
      • Waterproof Covers
      • Fire Training Accessories
      • Gas Regulators
      • Power Packs
      • Fluid Storage
    • Consumables
      • Fluids
      • Smoke Aerosols
      • CO2/Nitrogen/Inert Gas
  • Hire
    • Hire Overview
    • Air Trace Hire
    • B1 Hire
    • Colt 3 Hire
    • Colt 4 Hire
    • Artem Hire
    • Spirit 900 Hire
    • ViCount & Vulcan Hire
    • Miscellaneous Hire Items
  • Services
    • Services Overview
    • Consultancy Advice
    • Design & Manufacture
    • Smoke Testing
    • Hire Operators
    • Servicing & Maintenance
  • FAQs
  • Concept
    • About Us
    • Latest News
    • Worldwide Presence
    • Case Studies
    • Quality Assurance
    • Contact Us
Got a question?
Concept Smoke Systems > Products > Smoke Generators > Portable Mains Operated > Colt 4 Turbo

Products

Colt 4 Turbo

The Turbo variant of our best selling Colt 4 incorporates a much larger mass, precision machined heat exchanger block, and 2 x 1100w Firerod cartridge heaters switched via a solid state relay.
Key Points
  • The most powerful, hand held generator in its class with off power capability
  • Manufactured by Concept in the UK under ISO 9001
  • Compact size, robust construction, splashproof switches/indicators and NATO codified
  • Designed for Fire Training, Leak Testing, Air Flow Visualisation, Spray Booth Clearance Tests
  • Extremely persistent smoke with a particle size 0.2 micron mmd

Colt 4 Turbo Brochure
Material Safety Data Sheet
Available for Hire
Pricing

SKU: C4TUR Categories: Portable Mains Operated, Smoke Generators Tags: Handheld, Hire, Portable, Smoke Generator
  • Description

Description

The result – almost twice the smoke output of the standard Colt 4, and the ability to make smoke “Off Power” for longer – because it has a greater amount of retained energy within the heat exchanger.

With its enhanced performance, the Colt 4 Turbo is capable of smoke logging larger volumes, more quickly, and to denser smoke concentrations than any other similar system. However, the smoke output is completely adjustable, so, if required, smoke output can be reduced from a powerful plume to a small wisp.

In service with numerous fire authorities world-wide, many NATO forces (including the USN and Royal Navy for shipboard training), as well as analytical laboratories, asbestos removal specialists, and HVAC and LEV contractors, the Concept Colt has an enviable reputation for simplicity of operation and reliability.

The entire Royal Navy and Royal Fleet Auxiliary, after extensive testing, have equipped their entire fleet with the Colt 4 Turbo smoke systems for creating safe but highly realistic fire training scenarios.

As with any of Concept’s mains powered smoke generators the Colt 4 Turbo really is built to last. As standard the unit comes with a 5 year warranty & lifetime guarantee on heater block.

The unit uses the standard, one piece aluminium Colt 4 smoke can to produce an extremely persistent smoke. The can contains both the smoke chemical and the INERT propellant gas required to make the smoke. The canister automatically re-seal after use, so they can be used time and time again until exhausted.

The Colt 4 Turbo creates a smoke with such a small particle size, meaning much lower chemical concentrations to achieve and maintain specific smoke concentrations than conventional smoke systems. For fire training purposes this means that much safer (and more realistic) conditions can be achieved.

All Concept Colts have an enviable reputation for simplicity of operation and reliability.

Remote operation is available on the Colt 4 Turbo. A choice between a wired remote and radio remote control to suit all applications.

The use of the canisters reduces the number of moving parts within the machine to just one, resulting in exceptional serviceability and reliability.

The resulting smoke from the Colt 4 Turbo has a particle size of just 0.2-0.3 micron mmd. The smallest particle size in it’s class. This compares to typical entertainment smoke systems that have a particle size of 1-5 microns. This means the Colt 4 Turbo doesn’t just create the most persistent water based smoke available, it is also the safest. In normal operation, once the smoke has been produced and vented the class leading particle size of the Colt 4 Turbo means that there will be no discernible residue.

Re-fillable aerosol cans are also available if required which can simply be pressurised by a hand pump, airline or inert gas supply.

Available as 110v/230v smoke generator.

Related products

  • Vulcan 5000

    Read more
  • Flow Check

    Read more
  • Colt 4 Twin Turbo

    Read more
FPA member logo
NQA ISO oogo
JOSCAR logo
Cyber Essentials logo
Contact Us

Concept Engineering Ltd
7 Woodlands Business Park
Woodlands Park Avenue
Maidenhead
Berkshire
SL6 3UA
United Kingdom

+44 (0)1628 825 555
info@conceptsmoke.com

Smoke Systems
  • About Smoke Overview
  • Applications Overview
  • Hire Overview
  • FAQs
Products
  • Smoke Generators
  • Security Smoke Systems
  • Accessories
  • Consumables
Concept
  • About Us
  • Latest News
  • Worldwide Presence
  • Case Studies
  • Contact Us
©2025 Concept Engineering Ltd | All Rights Reserved.
Website development by Virtualnet.

Got a question?

Leave a message and we'll get straight back to you or give us a call.

+44 (0)1628 825 555

info@conceptsmoke.com