Concept Smoke Scrubbers

The range of Smoke Scrubbers from Concept are designed to clear areas that have been filled with artificial smoke.  We have several different units available for different size applications. 

For many years Concept Smoke Systems have produced specialist aerosol and smoke generating equipment for the chemical, biological and nuclear industries, for testing the efficacy of the HEPA fitters in these "Cleanroom" environments.  


General Specification (approx) CEL SS 800 CEL SS 2000  CEL SS 5000
Flow Rate M3/Hr 800 M3/Hr 2250 M3/Hr 5450
Weight 18 kg 43 kg 82 kg
Dimensions 42 x 45 x 46 cm 50 x 56 x 94 cm 71 x 85 x 113 cm
Electrical Options 50Hz

110v / 230v

2.2A / 1.1A running 

110v / 230v

11A / 5.5A running 

110v / 230v

25A / 12A running 

Input spigot  dia 30 cm 30 cm  40 cm
Typically suitable for cleaning room volumes of 160m³ in 15 minutes. Typically suitable for clearing room volumes of 250-300m³ in 15 minutes. Typically suitable for clearing room volumes of 600-700m³ in 15 minutes.

Concept have now utilised that technology in producing a range of "Smoke Scrubbers" that can quickly and efficiently draw in smoke laden air and produce clear air on the output side of the HEPA filter bank.

This means that users who have a requirement to produce smoke in an internal environment where normal venting of the smoke would be impractical can still clear smoke laden air from that environment at the touch of a button.

These units are ideal for clearing smoke laden air from aircraft simulators, computer suites or any area where venting to outside is impractical or undesirable.  They are also heavily used in the nuclear and pharmaceutical industries.

The Negative Pressure Units are easily cleaned and can be split apart for ease of carrying upstairs or transporting to and from site.

 

Replacement filters are readily available.

If necessary, the Smoke Scrubbers can be mounted adjacent to the room or enclosure being vented, and the smoke extracted from that enclosure via a flexible hose. Typically, for example, in aircraft simulator applications, the Smoke Scrubber is mounted in the simulator hall, and a suitable umbilical hose is taken from the input side of the Scrubber to the Simulator cabin.

Want more information, advice or prices? email us: info@conceptsmoke.com

Smoke Scrubbers

CEL SS 800 Smoke Scrubber            

Product Codes: CEL-SS-800  

Technical specification above. Available in both 110v or 230v. Supplied with pre and Hepa filter (installed)  &  input spigot plate.

Approx. maximum airflow with clean filter: 800m3 per hour.


CEL SS 2000 Smoke Scrubber           

Product Codes: CEL-SS-2000  

Technical specification above. Available in both 110v or 230v. Supplied with pre and Hepa filter (installed) & input spigot plate.

Approx. maximum airflow with clean filter: 2250m3 per hour.


CEL SS 5000 Smoke Scrubber 

Product Code: CEL-SS-5000

Technical specification above. Available in both 110v or 230v. Supplied with pre and Hepa filter (installed) & input spigot plate.

Approx. maximum airflow with clean filter: 5950m3 per hour / 3880cfm.

 

Smoke Scrubber Accessories

Spare Smoke Scrubber Gauge

Product Code: CEL-NPU-GAUGE

Spare gauges suitable for all the Smoke Scrubbers.  Requires a 64mm hole.  


Pre Filter - Smoke Scrubber

Product Code: CEL-SS-800-PF, CEL-SS-2000-PF, CEL-SS-5000-PF

Spare / replacement Pre Filters are available for each of the Smoke Scrubbers.


HEPA Filter - Smoke Scrubber

Product Code: CEL-SS-800-HF, CEL-SS-2000-HF, CEL-SS-5000-HF

Spare / replacement HEPA filters are available for each of the Smoke Scrubbers.


Want more information, advice or prices? email us: info@conceptsmoke.com 

Demonstration movies

Smoke Scrubber

Downloads

Concept Smoke Scrubbers 2021
latest news

Latest News

> view all articles

Colt 4 Twin Turbo - New Product

Concept Smoke Systems are one of the leading smoke machine manufacturers... Read more >


ESS 2015

Concept are pleased to be exhibiting and supporting the Emergency Servic... Read more >

> view all

Testimonials

Building Envelope Technologies Ltd

"We have been using the ViCount unit now for some time as our main method of generating smoke for air leakage path identification as part of building airtightness tests.

The speed at which the unit builds smoke is very impressive and consistently in line with the guidance given by yourselves.

The nature and density of the smoke produced proves very effective when observed from outside the building giving sufficient time for and allowing easy observation of emerging smoke and leakage paths. The very persistent effect has allowed us to test buildings with volumes up to 40,000 m3 with just two units.

The very dry nature of smoke (i.e. small particle size) has meant that there have been no instances of contamination of the buildings following the test.

We have found the continuing technical support provided by Concept to be prompt and effective in answering queries and allowing us to get the most out of our equipment."